Home > Facilities > Bioimaging Room
Manufacturer | Carl Zeiss Microscopy |
---|---|
Model number | LSM780 with Airyscan |
Type of use | self-use |
Overview | Inverted microscope AxioObserverZ1 system with confocal laser scanning microscope LSM780 and Multi-functional ultra-sensitive array GaAsP detector Airyscan |
Spec | Objective: Plan-Apochromat 10x/0.45, 20x/0.8, 40x/1.4Oil, 63x/1.4Oil, 100x/1.46Oil, C-Apochromat 40x/1.2W Laser: Diode 405nm (25mW), Ar 458/488/514nm (25mW), DPSS 561nm (20mW), HeNe 633nm (5mW) Detector: 32ch (GaAsP) + 2ch for fluorescence, 1ch for transmitted light, Airyscan Others: motorised stage, stage top incubator |
Outside User | Impossible |
Booking | https://chem-eqnet.ims.ac.jp/ |
Remarks | Training participants are required within the research laboratory. New users can use the facilities after receiving training from the training participants. |
Manufacturer | Carl Zeiss Microscopy |
---|---|
Model number | LSM780 |
Type of use | self-use |
Overview | Upright microscope AxioImagerZ2 system with confocal laser scanning microscope LSM780 |
Spec | Objective: Plan-Apochromat 10x/0.45, 20x/0.8, 40x/1.4Oil, 63x/1.4Oil, W-Plan-Apochromat 40x/1.0 Laser: Diode 405nm (25mW), Ar 458/488/514nm (25mW), DPSS 561nm (20mW), HeNe 633nm (5mW) Detector: 32ch (GaAsP) + 2ch for fluorescence, 1ch for transmitted light |
Outside User | Impossible |
Booking | https://chem-eqnet.ims.ac.jp/ |
Remarks | Training participants are required within the research laboratory. New users can use the facilities after receiving training from the training participants. |
Manufacturer | Carl Zeiss Microscopy |
---|---|
Model number | Axio Observer Z1 |
Type of use | self-use |
Overview | Inverted microscope AxioObserverZ1 system with high-sensitivity CCD camera |
Spec | Objective: EC Plan-Neofluar 10xPh/0.3, LD20xPh/0.4, LD40xPh/0.6, Plan-Apochromat 63x/1.4Oil Filter: DAPI, GFP, RFP, Cy5. Light source: LED 365nm, 470nm, 540-580nm, 625nm Camera: high-sensitivity CCD camera ORCA Flash4 Function: superimposition, time-lapse, deconvolution |
Outside User | Impossible |
Booking | https://chem-eqnet.ims.ac.jp/ |
Remarks | Training participants are required within the research laboratory. New users can use the facilities after receiving training from the training participants. |
Manufacturer | Carl Zeiss Microscopy |
---|---|
Model number | Axio Zoom V16 |
Type of use | self-use |
Overview | Zoom microscope system with high-sensitivity CCD camera |
Spec | Objective : 1.0x/0.25FWD56mm, 2.3x/0.57FWD10.6mm. Fluorescence filters: DAPI, GFP, DsRed Camera: high-sensitivity CCD camera AxioCamMRm Function: superimposition, tiling, Z-stack |
Outside User | Impossible |
Booking | https://chem-eqnet.ims.ac.jp/ |
Remarks | Training participants are required within the research laboratory. New users can use the facilities after receiving training from the training participants. |
Manufacturer | Carl Zeiss Microscopy |
---|---|
Model number | IMARIS |
Type of use | self-use |
Overview | Extensive display and analysis of 3D/4D images created by confocal laser scanning microscopes |
Spec | Imaris |
Outside User | Impossible |
Booking | https://chem-eqnet.ims.ac.jp/ |
Remarks | Training participants are required within the research laboratory. New users can use the facilities after receiving training from the training participants. |
Manufacturer | Carl Zeiss Microscopy |
---|---|
Model number | IMARIS2 |
Type of use | self-use |
Overview | Extensive display and analysis of 3D/4D images created by confocal laser scanning microscopes |
Spec | Imaris, Measurement Pro, Coloc, Filament Tracer, Cell |
Outside User | Impossible |
Booking | https://chem-eqnet.ims.ac.jp/ |
Remarks | Training participants are required within the research laboratory. New users can use the facilities after receiving training from the training participants. |
Manufacturer | YAMATO KOHKI |
---|---|
Model number | RX-860 |
Type of use | self-use |
Overview | Rotary microtome developed for thin-slicing performance |
Spec | Slice thickness setting range: 0.1 – 500.0 µm (dial system). Vertical stroke length: 70 mm Front-back stroke length: 40 mm Function: retraction, counter, trip meter, feed lock |
Outside User | Impossible |
Booking | https://chem-eqnet.ims.ac.jp/ |
Remarks | Training participants are required within the research laboratory. New users can use the facilities after receiving training from the training participants. |
Manufacturer | Tomocube |
---|---|
Model number | HT-2 |
Type of use | self-use |
Overview | Label-free quantitative imaging |
Spec | Lens Type: 60 X NA 1.2 (WATER IMMERSION) Lateral Resolution: 110nm Axial Resolution: 356nm Time Res.: 150 fps (2D), 2.5 fps (3D) Basic(diode laser): 532 nm Fluorescence(LED): Blue: 385 nm, Green: 470 nm, Red 570 nm |
Outside User | Impossible |
Booking | https://chem-eqnet.ims.ac.jp/ |
Remarks | Training participants are required within the research laboratory. New users can use the facilities after receiving training from the training participants. |
Manufacturer | Evident |
---|---|
Model number | APX100 |
Type of use | self-use |
Overview | Benchtop microscope system for brightfield, phase contrast, and fluorescence observation. APX100 supports a wide range of research imaging applications including slides, dishes, and well plates. A wide range of imaging methods, including multicolor imaging, Image Stitching, time-lapse, and Z-stacking, can be used in any combination that fits your research protocol. |
Spec | Objective: 4x/0.13, 10x/0.3, 20x/0.7 WD0.8-1.8mm, Apocromat 40x/0.95, Apocromat 100x/1.45 Oil Transillumination: Köehler illumination, LED light source Stage: Motorized XY stage Filters: B excitation (U-FBNA), U excitation (U-FUNA), G excitation (U-FGW), CY5 (U-DM3-CY5) Camera: 1/1.8″ 6.41 megapixel color CMOS, 1/1.8″ 6.41 megapixel monochrome CMOS |
Outside User | Impossible |
Booking | https://chem-eqnet.ims.ac.jp/ |
Remarks | Training participants are required within the research laboratory. New users can use the facilities after receiving training from the training participants. |